Applications
These individuallycopper screened cables are used for wiring of machines, or between machines and equipment where PVC is suitable
Standards
AS/NZS 1972:2006
AS/NZS 1125
AS/NZS 3808
Construction
Conductors: Stranded copper conductor.
Insulation: PVC.
Bedding: Polyester tape.
Collective Composite Screen (earth conductor): Tinned annealed copper braiding interwove with polyester yarn.
Sheath: PVC sheath.
Dimensions and Weight
NUMBER OF CORES | NOMINAL CONDUCTOR AREA | STRAND SIZE | INSULATION THICKNESS | CORE SCREEN | THICKNESS OF SHEATH | NOMINAL OVERALL DIAMETER | NOMINAL WEIGHT |
---|
STRAND SIZE | AREA OF SCREEN |
---|
| MM² | NO/MM | MM | MM | MM² | MM | MM | KG/100M |
---|
Type 1 – Collectively Screened |
2 | 1.5 | 30/0.25 | 0.8 | 0.20 | 2.3 | 0.8 | 9.2 | 12 |
3 | 1.5 | 30/0.25 | 0.8 | 0.20 | 2.5 | 0.8 | 9.7 | 15 |
4 | 1.5 | 30/0.25 | 0.8 | 0.20 | 2.6 | 0.8 | 10.5 | 18 |
6 | 1.5 | 30/0.25 | 0.8 | 0.20 | 3.4 | 0.8 | 12.6 | 25 |
16 | 1.5 | 30/0.25 | 0.8 | 0.20 | 5.1 | 1.0 | 18.7 | 55 |
30 | 1.5 | 30/0.25 | 0.8 | 0.25 | 8.8 | 1.3 | 24.6 | 96 |