Applications
These Type A & B 1.1/1.1KV Mining cables are used as 1.1kV cables to distribute power within themine,suitable for use in underground coal mines. For Type A cables,optional 3 pilots can be selected.
Standards
AS/NZS 1972:2006
AS/NZS 1125
AS/NZS 3808
Construction
Conductors: Stranded tinned annealed copper conductor.
Insulation: EPR.
Filling: Elastomer centre filler.
Optional Pilot Core (Type A only): CPE compositeinsulated and covered pilot conductor.
Screen (earth conductor): Copper wire.
Sheath: Heavy duty PCP sheath.
Dimensions and Weight
NOMINAL CONDUCTOR AREA | STRAND SIZE | INSULATION THICKNESS | CORE SCREEN | PILOT CONDUCTOR | NOMINAL SHEATH THICKNESS | NOMINAL OVERALL DIAMETER | NOMINAL WEIGHT |
---|
STRAND SIZE | AREA OF SCREEN | STRAND SIZE | THICKNESS OF COVERING |
---|
MM² | NO/MM | MM | MM | MM² | NO/MM | MM | MM | MM | KG/100M |
---|
Type A & B |
16 | 7/1.70 | 1.4 | 48/0.40 | 6.0 | 24/0.20 | 1.6 | 2.5 | 24.6 | 120 |
25 | 19/1.35 | 1.4 | 57/0.40 | 7.2 | 32/0.20 | 1.8 | 2.5 | 28.0 | 170 |
35 | 19/1.53 | 1.5 | 63/0.40 | 7.9 | 30/0.25 | 1.8 | 2.5 | 30.4 | 205 |
50 | 19/1.78 | 1.7 | 72/0.40 | 9.0 | 50/0.25 | 2.0 | 3.0 | 34.9 | 270 |
70 | 19/2.14 | 1.8 | 67/0.50 | 13.2 | 80/0.25 | 2.0 | 3.3 | 40.2 | 370 |
95 | 19/2.52 | 2.0 | 77/0.50 | 15.1 | 80/0.25 | 2.0 | 3.8 | 46.1 | 490 |
120 | 37/2.03 | 2.2 | 65/0.67 | 22.9 | 80/0.25 | 2.0 | 3.8 | 51.1 | 615 |
150 | 37/2.25 | 2.3 | 70/0.67 | 24.7 | 80/0.25 | 2.0 | 4.4 | 56.0 | 740 |
185 | 37/2.52 | 2.5 | 78/0.67 | 27.5 | 80/0.25 | 2.0 | 5.1 | 62.3 | 915 |
240 | 61/2.25 | 2.7 | 45/1.35 | 64.4 | 80/0.25 | 2.0 | 5.7 | 72.9 | 1290 |