Application
These durable, high temperature resistant LSOH cables are designed for wind turbines and dedicated for fixed installation inside the tower.
Standards
Construction
Conductor | Aluminium conductor, class 2 according to IEC 60228/EN 60228 |
Insulation | Special cross-linked halogen free rubber EPR for high temperatures |
Sheath | Special cross-linked synthetic halogen free rubber EM8 (XLEVA). CPE can be offered upon request. |
Technical Data
RATED VOLTAGE U0/U (UM) | 0.6/1kV |
---|
OPERATING TEMPERATURES | -40℃~+90℃ |
---|
MINIMUM BENDING RADIUS | 6×OD |
---|
MAXIMUM PERMISSIBLE TENSILE LOAD | 15 N/mm^2 |
---|
SHORT-CIRCUIT TEMPERATURE | 250℃ |
---|
FLAME RETARDANT | IEC 60332-1/ IEC 60332-3 |
---|
HALOGEN FREE | IEC 60754 |
---|
CORROSIVE GASES | IEC 60754 |
---|
SMOKE DENSITY | IEC 61034 |
---|
OIL RESISTANT | Yes |
---|
OZONE RESISTANT | Yes |
---|
UV RESISTANT | Yes |
---|
WATER RESISTANT | Yes |
---|
Dimensions and Weight
CONSTRUCTION | NOMINAL OVERALL DIAMETER | NOMINAL WEIGHT |
---|
NO. OF CORES×MM^2 | MM | KG/KM |
---|
1×150 | 22.5 | 640 |
1×185 | 25.0 | 770 |
1×240 | 27.8 | 980 |
1×300 | 30.5 | 1210 |
1×400 | 35.5 | 1550 |