Tianjin Feiya Wire&Cable Co.,Ltd

Product Detail
Fire Resistant Medium Voltage Power Cables Water Blocked P6 or P6/P13 BFOU 3.6/6kV
Detail

Applications

  • These cables are partially water blocked, fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.

Standards

  • IEC 60092-353IEC 60092-351
    IEC 60092-359IEC 60332-1
    IEC 60332-3-22IEC 60754-1,2
    IEC 61034-1,2NEK 606:2004
    VG 95218 part 29

Water Blocked P6 or P6/P13 BFOU 3.6/6kV

Construction

  • Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2.
    Conductor Screen: Semi conducting material.
    Insulation: Mica tape + Halogen free EPR.
    Insulation Screen: Semi conducting material and tinned copper wire braid.
    Filler: Water blocking fillers, if required.
    Bedding: Halogen free compound, PETP wrapping tape will be applied over the bedding, if required.
    Armour: Tinned copper wire braid, PETP wrapping tape will be applied over the braiding, if required.
    Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.
    Inner Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P6), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P6/P13), coloured red.
    Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.

Electrical Characteristics

  • Nominal Cross Section Areamm22535507095120150
    Nominal Conductor Diametermm6.57.48.710.312.213.815.1
    Maximum DC Resistant@20˚CO/km0.7340.5290.3910.270.1950.1540.126
    Continuous Current Rating@45˚C1 CoreA127157196242293339389
    Continuous Current Rating@45˚C3 CoreA89110137169205237272
    Short Circuit Current 1sA35805010715010020135901717021460
    Operating VoltageKV3.6/63.6/63.6/63.6/63.6/63.6/63.6/6
  • Nominal Cross Section Areamm2185240300400500630
    Nominal Conductor Diametermm17.019.621.924.527.532.3
    Maximum DC Resistant@20˚CO/km0.10.07620.06070.04750.03690.0286
    Continuous Current Rating@45˚C1 CoreA444522601690780890
    Continuous Current Rating@45˚C3 CoreA311365421483546623
    Short Circuit Current 1sA264703434042930572307154090140
    Operating VoltageKV3.6/63.6/63.6/68.7/158.7/158.7/15

Ambient Temperature Correction Factors

  • Ambient Temperature Correction Factors35404550556065707580
    Rating Factor1.11.051.00.940.880.820.740.670.580.47

Mechanical and Thermal Properties

  • Bending Radius :15×OD (during installation); 9×OD (fixed installed).

  • Temperature Range : -20˚C ~ +90˚C.

Dimensions and Weight

Construction No. of

cores×Cross

section

(mm2)

Nominal Insulation Thickness

mm

Nominal Bedding

Thickness

mm

Nominal Inner

Sheath Thickness

mm

Nominal Outer Sheath Thickness

mm

Nominal Overall Diameter

mm


Nominal Weight

kg/km

1×162.51.51.2126.8±2998
1×252.51.61.21.228.7±21166
1×352.51.61.21.230.0±21323
1×502.51.71.31.231.5±21533
1×702.51.71.31.233.3±21827
1×952.51.81.41.436.0±22216
1×1202.51.91.41.437.7±22552
1×1502.51.91.41.439.7±23035
1×1852.521.51.441.9±23539
1×2402.62.11.61.645.4±24305
1×3002.82.21.61.647.9±25051
1×40032.31.71.651.3±26101
1×5003.22.51.81.655.3±27382
1×6303.22.61.91.659.7±29062
3×162.52.31.7149.8±23728
3×252.52.51.81.253.9±24389
3×352.52.61.91.257.1±25061
3×502.52.71.91.259.8±25765
3×702.52.821.264.0±26920
3×952.532.11.469.0±28316
3×1202.53.12.21.472.9±29608
3×1502.53.32.31.476.8±210983
3×1852.53.42.41.481.4±212611
3×2402.63.72.61.689.5±215425
3×3002.83.92.81.695.1±217987