EPR/CSP 0361 TQ H0FR Welding Cable Single Core EPR Insulated CSP sheathed to BS 638 Part4 85 Deg 100

Detail

CONSTRUCTION :                       

Conductor: Extra Flexible Class6 Tinned/Plain Copper to BS6360. Flexible Class 5 for 120 mm sq and above

Separator: Crepe Paper /PETP Tape

Insulation: Ethylene Propylene Rubber (E.P.R.) to BS 7655

Sheath: Chlorosulphonated Polythylene (C.S.P.) H.O.F.R. ( Heat and Fire Retardant ) to BS 7655

Sheath Color: Orange ( Tinned conductors ) Black ( Plain conductors )

Flexible aluminium conductors available upon request.

APPLICATION :
This range of Cables are designed as highly flexible voltage leads, primarily for the secondary (high current) connection to automatic or hand held metal arc welding electrodes .
May also be used for non welding applications such as earthing return leads, flexible tails on power supply. Busbar connections.

TECHNICAL DATA
:
Voltage: 100V (If used in an environment where they are not liable to sustain mechanical damage these Cables may be used at 450/700V in the control panels, switchgears etc.
Temperature Rating: -20 to +85°C
Bending Radius:
6 x Overall Diameter

RATING FACTORS :

The current ratings given are based on an ambient temperature of 25 Deg. Rating factors for higher temperatures are: Ambient Temp: 30 Deg 35 Deg 40 Deg 45 Deg Rating Factor: 0.96 0.91 0.87 0.82 Where total cable lengths in excess of 15m are involved, it may be necessary to use cable of larger cross section to ensure that the voltage drop is not excessive and welding currents are maintained at adequate levels.

DUTY CYCLE :

The duty cycle is defined as the time for which the current flows expressed as a percentage of the complete cycle, which is taken as 5 minutes. Since the length of time for which current flows during a welding operation varies, occasional to continuous, the duty cycle can vary from as little as 20% to a maximum of 100% on automatic operation.

Automatic Welding up to 100%.
Semi Automatic Welding 30-85%.
Manual Welding 30-60%.
Intermittent or Occasional Welding up to 20%.

Size MMStranding ClassStranding MMThickness of Sheath mmNominal O/Dia MMWeight Kg / KmMax Duty Cycle 100%Max Duty Cycle 60%Max Duty Cycle 30%
166513 / 0.202.010.9212135175245
256783 / 0.202.012.5300180230330
3561107 / 0.202.014403225290410
5061566 / 0.202.216560285370520
7062214 / 0.202.418.6776355460650
9562997 / 0.202.621.21035430560790
1205608 / 0.502.823.11300500650910
1855925/0.503.229.020506608501200

Electrical Characteristics

Electrical Characteristics

Loading Current Values (amperes)

Nominal Cross Sectional Area mm2Loading Current in Amps for the Following Duty Cycles
mm2100%85%60%30%
16135145175245
25180195230330
35225245290410
50285310370520
70355385460650
95430470560790
120500540650910
1856607158501200

Correction Factors

Cable operating temperature also varies according to the prevailing ambient temperature. These cables are designed to give optimum performance up to an operating temperature of 85°C at an ambient temperature of 25°C. The reduction factors for increased ambient temperature are:
Ambient Temperature30°C35°C40°C45°C50°C55°C
Correction Factor0.960.910.870.820.760.79

Conductor Resistance (ohms per kilometre) and Voltage Drop

Nominal Cross Sectional AreaMaximum Resistance at 20°C TinnedVoltage Drop (For Guidance Only)
Volts Per 100 Amp Per 10 Metres DC Current *
20°C60°C85°C
mm2ohms/KmVVV
161.2401.2401.4301.560
250.7950.7950.9200.998
350.5650.5650.6540.709
500.3930.3930.4550.493
700.2770.2770.3210.348
950.2100.2100.2460.264
1200.1640.1640.1900.206
1850.1080.1080.1250.136
*Note:
The values for AC Current may be much higher, depending on the configuration of the cables.