Application
These screened, halogen-free cables are designed for special purpose of data transmission in wind turbines, suitable for indoor and outdoor installation.
Standards
Construction
Conductor | Stranded bare copper. |
Insulation | Halogen free compound. |
Screen | Tinned copper wire braid. |
Sheath | Halogen free compound. |
Technical Data
Rated Voltage Uo/U (Um) | 250V |
Operating Temperatures | flexing: -5℃~+70℃; fixed: -40℃~+70℃ |
Minimum Bending Radius | flexing: 10×OD; fixed: 7.5×OD |
Flame Retardant | DIN VDE 0482 part 265-2-1/EN 50265-2-1/IEC 60332-1 |
Halogen Free | VDE 0482 part 267/DIN EN 50267-2-1/IEC 60754 |
Gases Corrosively | VDE 0482 part 267/DIN EN 50267-2-2/IEC 60754 |
Oil Resistant | Yes |
Dimensions and Weight
CONSTRUCTION | NOMINAL OVERALL DIAMETER | NOMINAL WEIGHT |
---|
NO. OF CORES×MM2 | MM | KG/KM |
---|
2×0.14 | 4.1 | 22 |
3×0.14 | 4.3 | 25 |
4×0.14 | 4.5 | 29 |
6×0.14 | 5.1 | 35 |
7×0.14 | 5.1 | 38 |
8×0.14 | 6.0 | 41 |
12×0.14 | 6.5 | 78 |
16×0.14 | 7.2 | 90 |
25×0.14 | 8.7 | 149 |
2×0.25 | 4.7 | 25 |
3×0.25 | 4.9 | 30 |
4×0.25 | 5.2 | 35 |
6×0.25 | 6.2 | 49 |
7×0.25 | 6.2 | 52 |
8×0.25 | 7.3 | 58 |
10×0.25 | 7.7 | 81 |
25×0.25 | 10.9 | 172 |
2×0.34 | 5.1 | 30 |
3×0.34 | 5.3 | 35 |
4×0.34 | 5.9 | 42 |
5×0.34 | 6.4 | 53 |
7×0.34 | 7.0 | 73 |
8×0.34 | 8.0 | 84 |
10×0.34 | 8.5 | 101 |
16×0.34 | 9.6 | 160 |
25×0.34 | 12.1 | 259 |
2×0.5 | 5.8 | 38 |
3×0.5 | 6.1 | 47 |
4×0.5 | 6.5 | 67 |
5×0.5 | 7.2 | 76 |
6×0.5 | 7.8 | 84 |
7×0.5 | 7.8 | 91 |
8×0.5 | 8.9 | 131 |
10×0.5 | 9.5 | 135 |
12×0.5 | 9.8 | 177 |
18×0.5 | 11.7 | 239 |
25×0.5 | 13.9 | 352 |
2×0.75 | 6.2 | 45 |
3×0.75 | 6.5 | 69 |
4×0.75 | 7.2 | 80 |
5×0.75 | 7.8 | 99 |
7×0.75 | 8.3 | 120 |
12G0.75 | 10.7 | 168 |
18G0.75 | 12.4 | 237 |
2×1 | 6.5 | 72 |
3×1 | 7.0 | 90 |
4×1 | 7.5 | 109 |
7×1 | 8.8 | 171 |
10×1 | 11.2 | 184 |
12G1 | 11.3 | 205 |
16×1 | 12.5 | 250 |
19G1 | 13.1 | 291 |
2×1.5 | 7.7 | 90 |
3×1.5 | 8.1 | 115 |
5×1.5 | 9.5 | 176 |
12G1.5 | 13.0 | 271 |
18G1.5 | 15.5 | 400 |
15G2.5 | 19.8 | 587 |