Application
These flexible and robust cables are designed for industrial use, suitable for fixed and normal flexible installations.
Standards
EN 187000
IEC 60794-2
IEC 60794-2-20
ISO 11801
EN 50173-1
Construction
Core Type | Tight buffer. |
Strain Relief | Aramid yarns. |
Break-out Unit Sheath | LSZH. |
Central Strength Member | FRP strength member, covered with LSZH material as appropriate. |
Outer Sheath | LSZH. |
Technical Data
Operating Temperatures | -20℃~+70℃ |
Minimum Bending Radius | 75~175mm depend on No. of fibres |
Torsion Application | 5 cycles +/- 1 turn |
Flame Retardant | IEC 60332-1/IEC 60332-3 |
Halogen Free | IEC 60754 |
No Acid Matters | IEC 60754 |
Smoke Density | IEC 61034 |
UV Resistant | Yes |
Dimensions and Weight
CONSTRUCTION | TIGHT BUFFER FIBER DIAMETER | NOMINAL OVERALL DIAMETER | NOMINAL WEIGHT |
---|
NO. OF FIBRES | ΜM | MM | KG/KM |
---|
2 | 900+/-50 | 7.5 | 60 |
4 | 900+/-50 | 7.5 | 60 |
6 | 900+/-50 | 8.5 | 75 |
8 | 900+/-50 | 10.0 | 100 |
12 | 900+/-50 | 12.5 | 160 |
16 | 900+/-50 | 12.0 | 145 |
24 | 900+/-50 | 14.5 | 210 |