Application
These halogen free cables with increased tolerance to torsion application, improved behaviour against abrasion and extended temperature, UV and ozone resistant are specially designed for wind turbines.
Standards
UL/CSA 22.2
UL 758
HD 22.13
Construction
Conductor | Stranded annealed bare copper, class 5 according to DIN VDE 0295/HD 383/IEC 60228. |
Insulation | Special thermoset EPR for high temperature. Special cross-linked improved for EI8 and EI7 base on EPDM can be offered upon request. |
Sheath | Special halogen free thermoset XLEVA. High mechanical performance special crosslinked EM8 synthetic halogen free rubber based on CPE can be offered upon request. |
Technical Data
RATED VOLTAGE U0/U (UM) | CENELEC 450/750V; UL/CSA 600V |
---|
OPERATING TEMPERATURES | -40℃~+90℃ |
---|
MAXIMUM PERMISSIBLE TENSILE LOAD | 15 N/mm^2 |
---|
MINIMUM BENDING RADIUS | flexing: 6×OD; fixed: 4×OD |
---|
TORSION APPLICATION | +/-150°/m |
---|
SHORT-CIRCUIT TEMPERATURE | 250℃ |
---|
FLAME RETARDANT | IEC 60332-1/IEC 60332-3 |
---|
HALOGEN FREE | IEC 60754 |
---|
SMOKE DENSITY | LSF EN 61034/IEC 61034 |
---|
OIL RESISTANT | Yes |
---|
OZONE RESISTANT | Yes |
---|
UV RESISTANT | Yes |
---|
WATER RESISTANT | Yes |
---|
IMPACT RESISTANT | Yes |
---|
Dimensions and Weight
CONSTRUCTION | NOMINAL OVERALL DIAMETER | NOMINAL WEIGHT |
---|
NO. OF CORES×MM^2 | MM | KG/KM |
---|
1×25 | 13.5 | 371 |
1×35 | 15.0 | 482 |
1×50 | 18.7 | 730 |
1×70 | 19.3 | 888 |
1×95 | 23.0 | 1220 |
1×120 | 25.5 | 1540 |
1×150 | 28.8 | 1810 |
1×185 | 31.4 | 2210 |
1×240 | 33.8 | 2750 |
1×300 | 37.7 | 3520 |
1×400 | 41.4 | 4510 |
3×120 | 56.0 | 5200 |
3×150 | 61.5 | 6400 |
3×240 | 72.0 | 9780 |
3×25 | 30.0 | 1420 |
3×35 | 35.3 | 1850 |
3×50 | 39.8 | 2480 |
3×70 | 43.8 | 3180 |
3×95 | 49.0 | 4260 |
3×120 | 52.8 | 5490 |
4G25 | 32.8 | 1870 |
4G35 | 36.3 | 2320 |
4G50 | 42.5 | 3150 |
4G70 | 48.2 | 4240 |
4G95 | 53.5 | 5480 |
4G120 | 58.3 | 6950 |
G: with green-yellow earth core ×: without green-yellow earth core