Tianjin Feiya Wire&Cable Co.,Ltd

Product Detail
M2XSY 0.6/1 kV XLPE Insulated, PVC Sheathed Flame Retardant Power & Control Cables (Multicore)
Detail

M2XSY 0.6/1 kV XLPE Insulated, PVC Sheathed Flame Retardant Power & Control Cables (Multicore)

Applications

These cables are used as fixed installation cables in various electromechanical and electronic equipments of marine vehicle.Usable at all conditions in marine environment such as dry, wet or oily locations. Galvanized steel wire braided shield provides protection against mechanical stress and rodents. Due to its' flame retardant feature, it prevents the fire from spreading around. Thus it protects human life and equipment, during a fire.

Standards

  • IEC 60092-350/351/353/359

  • IEC 60332-1

  • IEC 60332-3

Construction

M2XSY
ConductorsClass 2 stranded copper conductor. (Class 5 is upon request)
InsulationHalogen-free, flame retardant XLPE.
BeddingFlame retardant compound.
Overall ScreenGalvanized steel wire braided.
Outer SheathFlame retardant and oil resistant PVC based compound (ST2). Dark Grey.

Core Identification

Two coresBlue, Brown.
Three coresBrown, Black, Grey.
Four coresBlue, Brown, Black, Grey.
Five coresBlue, Brown, Black, Grey, Black.
Multi coresWhite with black numbers.
With yellow/green (optional)
Two cores + earth (3G)Yellow/green, Blue, Brown.
Three cores + earth (4G)Yellow/green, Brown, Black, Grey.
Four cores + earth (5G)Yellow/green, Blue, Brown, Black, Grey.

Mechanical and Thermal Properties

Bending Radius for Fixed Installations6×OD
Temperature Range-30℃ ~ +80℃

Dimensions and Weight

Part No.Construction No. of elements×No. of cores in element×Cross sectionNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterNominal Weight
mm²mmmmmmkg/km
M2XSY -2C1.02×1.00.71.110.4165
M2XSY -2C1.52×1.50.71.111.2195
M2XSY -2C2.52×2.50.71.112.0234
M2XSY -2C42×40.91.213.2296
M2XSY -2C62×60.91.214.8397
M2XSY -2C102×100.91.316.8539
M2XSY -2C162×160.91.418.8719
M2XSY -2C252×250.91.522.61055
M2XSY -2C352×350.91.525.01338
M2XSY -2C502×501.01.528.41756
M2XSY -3×1.03×1.00.71.110.9183
M2XSY -3C1.53×1.50.71.111.7217
M2XSY -3C2.53×2.50.71.112.6266
M2XSY -3C43×40.91.214.4372
M2XSY -3C63×60.91.315.5459
M2XSY -3C103×100.91.317.7642
M2XSY -3C163×160.91.419.9877
M2XSY -3C253×250.91.623.91290
M2XSY -3C353×350.91.626.41647
M2XSY -3C503×501.01.630.32200
M2XSY -3C703×701.01.635.23049
M2XSY -3C953×951.12.039.84061
M2XSY -3C1203×1201.12.144.35135
M2XSY -3C1503×1501.22.248.66173
M2XSY -4C1.04×1.00.71.111.8214
M2XSY -4C1.54×1.50.71.112.5251
M2XSY -4C2.54×2.50.71.214.1343
M2XSY -4C44×40.91.315.5441
M2XSY -4C64×60.91.316.9557
M2XSY -4C104×100.91.419.3784
M2XSY -4C164×160.91.521.71069
M2XSY -4C254×250.91.626.31605
M2XSY -4C354×350.91.729.12061
M2XSY -4C504×501.01.633.82300
M2XSY -4C704×701.12.139.43250
M2XSY -4C954×951.12.244.65194
M2XSY -5C1.05×1.50.71.212.6238
M2XSY -5C1.55×1.50.71.214.0318
M2XSY -5C2.55×2.50.71.215.1387
M2XSY -5G45G40.91.216.9510
M2XSY -6C1.06C1.00.71.213.3266
M2XSY -7C1.07C1.00.71.213.5271
M2XSY -8C1.08C1.00.71.213.6283
M2XSY -10C1.010C1.00.71.314.9308
M2XSY -12C1.012C1.00.71.415.6348
M2XSY -16C1.016C1.00.71.417.0375
M2XSY -19C1.019C1.00.71.517.8416
M2XSY -24C1.024C1.00.71.620.7508
M2XSY -27C1.027C1.00.71.221.2547
M2XSY -37C1.037C1.00.71.223.6689
M2XSY -6C1.56×1.50.71.214.7351
M2XSY -7C1.57×1.50.71.214.8362
M2XSY -8C1.58×1.50.71.214.9382
M2XSY -10C1.510×1.50.71.316.1390
M2XSY -12C1.512×1.50.71.416.9433
M2XSY -16C1.516×1.50.71.418.4470
M2XSY -19C1.519×1.50.71.519.5534
M2XSY -24C1.524×1.50.71.622.9662
M2XSY -5C2.55×2.50.71.214.9383
M2XSY -7C2.57×2.50.71.215.8453
M2XSY -12C2.512×2.50.71.418.5565
M2XSY -19C2.519×2.50.71.521.5725
M2XSY -24C2.524×2.50.71.625.2909
M2XSY -27C2.527×2.50.71.726.11160
M2XSY -37C2.537×2.50.71.929.21530