NEK606 Marine Cables Water Blocked P3 or P3/P10 RFOU/TFOU 6/10KV
Detail
Applications
These cables are partially water blocked, flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.
Standards
IEC 60092-353
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
VG 95218 part 29
Construction
Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable). Insulation Screen: Semi conducting material and tinned copper wire braid. Filler: Water blocking fillers, if required. Bedding: Halogen free compound, PETP wrapping tape will be applied over the bedding, if required. Armour: Tinned copper wire braid, PETP wrapping tape will be applied over the braiding, if required. Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness. Inner Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P3), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P3/P10), coloured red. Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.