These cables are partially water blocked, flame retardant, low smoke, halogen free and mud resistant, used for instrumentation, communication, control and alarm systems.
Standards
IEC 60092-376
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2
NEK 606:2004
VG 95218 part 29
Construction
Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Halogen free EPR compound. Twinning: Colour coded cores twisted together. Filler: Water blocking fillers, if required. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors. Bedding: Halogen free compound, PETP wrapping tape will be applied over the bedding, if required. Armour: Tinned copper wire braid, PETP wrapping tape will be applied over the braiding, if required. Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness. Inner Sheath: Halogen free thermosetting compound, SHF2 (for TYPE S2). Halogen free MUD resistant thermosetting compound, SHF MUD (for TYPE S2/S6), coloured grey (blue for intrinsically safe). Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.