Application
Single core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Insulation
Electron beam crosslinkable standard wall LSZH compound
Optional
FRA-SW-0.75S (Sheathed); FRA-SW-0.75S-OS (Screened & sheathed)
FRA-SW-0.75SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20℃
NOMINAL CONDUCTOR CROSS SECTION | MM² | 1.0 | 1.5 | 2.5 | 4.0 | 6.0 | 10 | 16 |
---|
MAXIMUM CONDUCTOR RESISTANCE | Ω/KM | 20 | 13.7 | 8.21 | 5.09 | 3.39 | 1.95 | 1.24 |
---|
VOLTAGE RATING | KV | 0.45/0.75 |
---|
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
CABLE CODE | NO. OF CORES& NOMINAL CONDUCTOR CROSS SECTIONAL AREA NO.×MM² | NOMINAL DIAMETER OF STRANDS MM | NOMINAL INSULATION THICKNESS MM | NOMINAL OVERALL DIAMETER MM | NOMINAL WEIGHT KG/KM |
---|
FRA-SW-0.75SU-1G1 | 1×1.0 | 32/0.2 | 0.8 | 3.9 | 28 |
FRA-SW-0.75SU-1G1.5 | 1×1.5 | 30/0.25 | 0.8 | 4.2 | 34 |
FRA-SW-0.75SU-1G2.5 | 1×2.5 | 50/0.25 | 0.8 | 4.6 | 41 |
FRA-SW-0.75SU-1G4 | 1×4.0 | 56/0.3 | 0.8 | 5.2 | 64 |
FRA-SW-0.75SU-1G6 | 1×6.0 | 84/0.3 | 0.9 | 6.4 | 93 |
FRA-SW-0.75SU-1G10 | 1×10.0 | 80/0.4 | 0.9 | 7.5 | 141 |
FRA-SW-0.75SU-1G16 | 1×16.0 | 126/0.4 | 1.1 | 8.6 | 203 |