Application
Single core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Insulation
Electron beam crosslinkable thin wall LSZH compound.
Optional
FRA-TW-1SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20℃
NOMINAL CONDUCTOR CROSS SECTION | MM² | 0.5 | 0.6 | 0.75 | 1.0 | 1.2 | 1.5 | 2.0 | 2.5 | 4.0 |
---|
MAXIMUM CONDUCTOR RESISTANCE | Ω/KM | 40.1 | 33.4 | 26.7 | 20.0 | 16.3 | 13.7 | 11.2 | 8.21 | 5.09 |
---|
VOLTAGE RATING | KV | 0.6/1.0 |
---|
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
CABLE CODE | NO. OF CORES& NOMINAL CONDUCTOR CROSS SECTIONAL AREA NO.×MM² | NOMINAL DIAMETER OF STRANDS NO/MM | NOMINAL INSULATION THICKNESS MM | NOMINAL OVERALL DIAMETER MM | NOMINAL WEIGHT KG/KM |
---|
FRA-TW-1SU-1C0.5S | 1×0.5 | 19/0.18 | 0.3 | 1.4 | 5.8 |
FRA-TW-1SU-1C0.6S | 1×0.6 | 19/0.20 | 0.3 | 1.5 | 7 |
FRA-TW-1SU-1C0.75S | 1×0.75 | 19/0.22 | 0.3 | 1.6 | 8.4 |
FRA-TW-1SU-1C1S | 1×1.0 | 19/0.26 | 0.3 | 1.75 | 10 |
FRA-TW-1SU-1C1.2S | 1×1.2 | 19/0.28 | 0.3 | 2.0 | 13 |
FRA-TW-1SU-1C1.5S | 1×1.5 | 19/0.30 | 0.3 | 2.15 | 16 |
FRA-TW-1SU-1C2S | 1×2.0 | 37/0.25 | 0.4 | 2.4 | 19 |
FRA-TW-1SU-1C2.5S | 1×2.5 | 19/0.40 | 0.4 | 2.75 | 26 |
FRA-TW-1SU-1C4S | 1×4.0 | 56/0.30 | 0.4 | 3.35 | 40 |